You have no items in your shopping cart.
Thermocouple Input
The most common measurement in data acquisition systems is temperature. The most commonly used sensor in temperature measurement is the thermocouple (TC). UEI provides a variety of thermocouple measurement boards compatible with our PowerDNA cube. In addition to the measurement boards, we also provide screw terminal connectivity panels that provide the high quality Cold-Junction temperature sensing required to make an accurate thermocouple measurement.
Software included with the PowerDNA performs linearization for all common TCs as well as cold-junction compensation. Users may choose to automatically receive data in either °C or °F. Users of non-standard TCs, or those who do not wish to utilize the built-in linearization routines, may also have data returned in Volts.
If you have any questions please call us at: (508)-921-4600 or email us at: info@ueidaq.com
| 6 Item(s) | Show per page |
| View as: Grid List |
Sort by
|
-
DNA-AI-207
16-channel, 18-bit, 1 kS/s per channel, analog input, data acquisition board
- 16 differential channels
- Additional dedicated CJC channel
- Maximum sampling rate of 1kHz per channel
- 18-bit resolution
- ±10V input range
- Gains - 1,2,4,8,10,20,40,80,100,200,400,800
- Overvoltage protection (-40V to +55V)
- Direct Inputs for thermocouples (with DNA-STP-AI-U panel)
- Embedded averaging engine
-
DNA-AI-217
16-Channel, 24-bit simultaneously sampling A/D board
- For use in “CUBE” chassis
- 16 differential analog input channels (+ one CJC channel)
- Simultaneous sampling (one A/D converter per channel)
- Direct Inputs for thermocouples (w/ DNA-STP-AI-U or DNA-STP-AI-207TC panel)
- 120 kHz per channel sample rate (480 kHz board max)
- 24-bit resolution
- Gains - 1, 2, 4, 8, 16, 32 and 64
-
DNA-AI-225
25-channel, 24-bit, 1 kS/s per channel, simultaneous sampling analog input, data acquisition board
- 25 channels
- 24-bit resolution
- One channel can be used for CJC
- 5 S/s to 1000 S/s sampling rates
- Differential inputs of ±1.25V
- Direct connection to thermocouples (using DNA-STP-AI-U terminal panel)
- Ideal for seismic testing, high-precision weight and temperature measurement
-
DNR-AI-207
16-channel, 18-bit, 1 kS/s per channel, analog input, data acquisition board for the PowerDNR RACKtangle®
- 16 differential channels
- Additional dedicated CJC channel
- Maximum sampling rate of 1kHz per channel
- 18-bit resolution
- ±10V input range
- Gains - 1, 2, 4, 8, 10, 20, 40, 80, 100, 200, 400, 800
- Overvoltage protection (-40V to +55V)
- Direct Inputs for thermocouples (with DNA-STP-AI-U panel)
- Embedded averaging engine
-
DNR-AI-217
16-Channel, 24-bit simultaneously sampling A/D board for PowerDNR RACKtangle®
- For RACKtangle® I/O chassis
- 16 differential analog input channels (+ one CJC channel)
- Simultaneous sampling (one A/D converter per channel)
- Direct Inputs for thermocouples (w/ DNA-STP-AI-U or DNA-STP-AI-207TC panel)
- 120 kHz per channel sample rate (480 kHz board max)
- 24-bit resolution
- Gains - 1, 2, 4, 8, 16, 32 and 64
-
DNR-AI-225
25-channel, 24-bit, 1 kS/s per channel, simultaneous sampling analog input, data acquisition board for the PowerDNR RACKtangle®
- 25 channels
- 24-bit resolution
- One channel can be used for CJC
- 5 S/s to 1000 S/s sampling rates
- Differential inputs of ±1.25V
- Direct connection to thermocouples (using DNA-STP-AI-U terminal panel)
- Ideal for seismic testing, high-precision weight and temperature measurement
| 6 Item(s) | Show per page |
| View as: Grid List |
Sort by
|