Skip to Main Content »

Welcome to the UEI Store

You're currently on:

PowerDNA Software Suite

Double click on above image to view full picture

Zoom Out
Zoom In

PowerDNA Software Suite

PowerDNA drivers and software, includes UEIDAQ Framework library
  • Supports Cube and RACKtangle chassis
  • Drivers for all Windows programming languages
  • MATLAB, LabVIEW and DASYLab drivers
  • ActiveX / OPC interface
  • Built-in hardware simulator
  • Includes RTX drivers
  • Includes TenAsys INtime driver
No Purchase necessary, however Add to Cart and Check Out are required for download

Availability: In stock.

Price: $0.00
Add Items to Cart
OR

Product Description

Windows software and drivers for PowerDNA/DNR hardware from UEI. Includes UEIDAQ Framework library, which includes support for the following:
  • VisualBASIC 6
  • VB.NET
  • OPC Server
  • MATLAB
  • LabWindows/CVI
  • LabVIEW
  • Excel
  • .NET
  • DASYLab
  • C#
  • C/C++
  • Borland Delphi
  • Borland C++ Builder
  • ActiveX


What's new in 4.4.0.12:
  • [Fixed] - Spurious timeout when running multiple cubes in ACB mode
  • [Fixed] - AI-224 calibration and ACB


What's new in 4.2.0.5:
  • SL-504 - Support added for new SL-604 layer
  • CT-601 - Implemented new Timed Period Pulse Measurement mode (TPPM)
  • AI-217 - Set correct default gain value.
  • DIO-401_4_5_6 - Implemented asynchronous events upon edge detection on input lines.
  • DIO-448 - Fix macro for single ended channels
  • 1553-708 - assignment of FIFO function for 1553-708 option changed so if one 1553-708 is in the system the functions will not be changed globally and affect all 1553 in the system
  • AI-255 - number of DC/DC required was calculated based on V while these DC/DC produce +/-V. This way we had excessive voltage on the op amps rails and dissipated it as waste heat. The voltage level to use extra DC/DC are converted into Vpp voltage in uV.
  • ARINC-429-566 - DQ_VMAP_RQSIZE_SZ processing is added to read_fifo_566() and write_fifo_566()
  • Debug log wraparound and position reporting is added
  • SL-508 - fix to allow 29.5Mhz baseclock for -892 option.
  • Fixed very old bug that prevents allocating the same DMAP more than 256 times. (This would happen for example when alternately creating/destroying two different DMAPS.)
  • SL-508: fixed baud rate error that was prevalent at higher baud rates
  • AI-217: code to accommodate the needs of UEI's calibration department. No functional difference to the user.
  • changed the default data filtering for pt-pt and DMAP modes to be in a more useful range.
  • MIL-1553: EV553_RT_CUST_LUT us implemented in drv_553.c for advanced 1553 customers
  • Custom pSL553CUST_LUT job for advanced 1553 customers - replace TX data of RT/SA upon receiving a predefined set of words in RX area
  • ARINC-708: BE and IFF printing is added
  • Big-endian/low-endian switch is added for TX and RX of ARINC-708 implementation.
  • SL-501/508: Implemented new mode that allows setting the parity bit independently on each byte sent over serial port.
  • ...and additional bug fixes


Changes made since PowerDNA 3.8.0.59
  • Support for 64 bits editions of Windows XP/Vista/7
  • Full support for new layer AO-358
  • Full support for new layer 1553-553 (MIL-1553)
  • Full support for new layer PC-91x.
  • New asynchronous operating mode.


Changes made since PowerDNA 3.8.0.55
  • Change ARP to prohibit packet queuing
  • Filter out broadcast UPD packets (i.e. NetBios)
  • Keep buffer allocated until IOCTL task finishes processing it
  • Insert check for correct format of IOCTL packets
  • Properly free packets on IOCTLR re-request
  • Increased pbuff size to avoid double allocations network buffer


Changes made since PowerDNA 3.8.0.53
  • Add AO regeneration for L3


Changes made since PowerDNA 3.8.0.30
  • [Fixed] - DIO-404 ACB write


Changes made since PowerDNA 3.8.0.26
  • [Fixed] - AI-211 PtByPt UeiDaqStopSession.vi doesn't close session
  • [Fixed] - time stamp reset issue in mpc5200 Ethernet firmware
  • [Fixed] - Add CPU logic revision to devtbl -l and HW Info Build completed:
  • [Fixed] - Add firmware build number to HW info


Changes made since PowerDNA 3.8.0.19
  • AO-308/332/333 DIO-4xx had a glitch on the output because of the bad MTU controller settings.
  • AI-254 4-wire external excitation mode ratiometric measurement fixed - use (signed)Sa/(signed)Sb provides proper position reading
  • Reset function is changed for 8347 build to allow proper reset of the rack
  • 201, 202, 207, 208 - timestamp fixed that there is no longer a need to use all channels for the timestamp to work properly
  • 403 - allow input and output to work in ACB mode simultaneously on the same channel
  • 566 - always returns even number of words from the layer if timestamp is enabled
  • 503 - reset changed to avoid inserting errors into the CAN bus upon chip reset
  • 205 - 801 option added (+/-4V without input divider)
  • Event is added to output CAN thread to prevent priority inversion situation with free-running thread.
  • For AO-3xx layers, SS0OUT is now used as the subsystem for writing output values
 

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

Recently Viewed Products

  1. UEILogger Software
  2. PowerDNA for QNX
  3. UEI-RSS
  4. DASYLab Runtime
  5. DASYLab 9 Pro
Download our Latest Catalog!

About UEI

For more than 15 years, UEI has made continuous efforts in the development of high performance, PC-based, data acquisition (DAQ) products, and support. Continuing to develop and manufacture new and uniquely powerful and configurable hardware is what makes UEI the right choice for data acquisition and control in multiple industries.
More About UEI »