Shopping Basket
  Home » FAQs » UEIPAC » Strain Gage Input
 Ethernet DAQ
· Data Acquisition and Control Chassis
· Analog Input
· Strain Gage Input
· Thermocouple Input
· Simultaneous Sampling
· LVDT/RVDT/Syncrho/Resolver
· Analog Output
· Digital I/O
· Counter/Timers/PWM/Quadrature
· Serial Communications
· CAN Bus
· ARINC 429
· MIL-STD-1553
· Power Conversion
· GPS Synchronization System
· PowerDNA Accessories
· Embedded Linux
 
 UEILogger
· UEILogger Cubes
· Analog Input
· Strain Gage Input
· Thermocouple Input
· Simultaneous Sampling
· Digital I/O
· Counter/Timers/PWM/Quadrature
· Serial Communications
· CAN Bus
· ARINC 429
· GPS Synchronization System
· Power Conversion
· UEILogger Accessories
 
 UEIPAC
· UEIPAC Cubes
· UEIPAC Linux Toolkit
· Analog Input
· Strain Gage Input
· Thermocouple Input
· Simultaneous Sampling
· Analog Output
· Digital I/O
· Counter/Timers/PWM/Quadrature
· Serial Communications
· CAN Bus
· ARINC 429
· GPS Synchronization System
· Power Conversion
· UEIPAC Accessories
 
 UEISIM
· UEISIM Cubes
· Analog Input
· Strain Gage Input
· Thermocouple Input
· Simultaneous Sampling
· Analog Output
· Digital I/O
· Counter/Timers/PWM/Quadrature
· Serial Communications
· CAN Bus
· ARINC 429
· GPS Synchronization System
· Power Conversion
· UEISIM Accessories
 
 UEIModbus
· UEIModbus Cubes
· Analog Input
· Strain Gage Input
· Thermocouple Input
· Simultaneous Sampling
· Analog Output
· Digital I/O
· Counter/Timers/PWM/Quadrature
· Power Conversion
· UEIModbus Accessories
 
 PCI/ISA Data Acquisition
· PD2-AO
· PD2-AO Accessories
· PD2-DIO
· PD2-DIO Accessories
· PDL-DIO
· PDL-DIO Accessories
· PD2-MF Data Acquisition
· PD2-MFS Data Acquistion
· PD2-MF(S) Accessories
· PDL-MF-Data-Acquisition
· PDL-MF Accessories
· PD2-LVRT
· UEI-800
· UEI-ISA-AO
· UEI-817
 
 PXI/CPCI data acquisition and control
· PDXI-AO
· PDXI-AO Accessories
· PDXI-DIO
· PDXI-DIO Accessories
· PDXI-MF Data Acquisition
· PDXI-MFS Data Acquisition
· PDXI-MF(S) Accessories
 
 Signal Conditioning
· PD-BUFF
· PD-SCXU-AOMUX
· PD-SSR
 
 Data Acquisition and Control Software
· DASYLab
· Linux Data Acquisition Software
· Real-Time Linux
· xPC Target
· UEIDAQ Framework
· QNX Data Acquisition and Control
· RTX Data Acquisition Drivers
· Embedded Linux
 
FAQ - Strain Gage Input
 

If you cannot find your answer in our FAQ database please fill out our Contact Support Form and we will respond with an answer.

 
Q000201: What kind of pre-filtering is possible? I don't see any. How does the system handle aliasing? 60Hz? Excitation current is limited to 120mA for all channels on the DNA-AI-208 ... this is not enough for me. I use 350 ohm QBs at 10V ... my current system (MEGADAC) provides 360mA. Suggestions?

Q000264: What is the correspondence between resolution in bits and percentile values for 12/16/24 bit data acquisition devices?

Q000267: Is there documentation on use of the AI-208 layer with strain gages?

Q000271: How long of a switching time of the multiplexer is needed to collect samples from channel to channel on the AI-201-100?

Q000272: When will UEI support the RoHS directive?

Q000275: I have set the excitation voltage on an AI-208. I measure nothing on my voltmeter. What's wrong?

Q000281: Does the 120mA limit on the DNA-AI-208 layer apply to the "total load", which is really the combined load of whatever two channels are on simultaneously?. Also, does this also mean that the layer must never drive a 120ohm bridge at 10 volts (which would consume 83mA)?

Q000286: Why does my thermocouple reading not go any higher than 739(or 422 or 985 etc.) degrees?

Q000305: What kind of pre-filtering is possible? I don't see any. How does the system handle aliasing? 60Hz? Excitation current is limited to 120mA for all channels on the DNA-AI-208 ... this is not enough for me. I use 350 ohm QBs at 10V ... my current system (MEGADAC) provides 360mA. Suggestions?

Q000306: What is the correspondence between resolution in bits and percentile values for 12/16/24 bit data acquisition devices?

Q000307: Is there documentation on use of the AI-208 layer with strain gages?

Q000308: How long of a switching time of the multiplexer is needed to collect samples from channel to channel on the AI-201-100?

Q000309: When will UEI support the RoHS directive?

Q000310: I have set the excitation voltage on an AI-208. I measure nothing on my voltmeter. What's wrong?

Q000346: What is the warm up time for the DNA-AI-201-100?
   [1]  2  Next »
Data Acquisition (DAQ) Glossary / Glossary (PDF) | Terms and Conditions | Email This Page | RSSRSS Feed
© 2008 United Electronic Industries, Inc. All rights reserved. Tel. (508) 921-4600; Fax (508) 668-2350.