Okay

Get in Touch

General
(508) 921-4600
Email Sales
Email Support

UEI Europe Office
+49 40 63698136
Email EU Sales

Visit this page for local offices and distributors.

Military style, Modbus TCP-based data acquisition and control I/O Chassis with 4 slots for I/O

UEIModbus 400-MIL

Features

  • Military/Rugged 38999 connectivity
  • 100% COTS solution
  • Industry standard Modbus TCP interface
  • Supported by over 90 I/O boards
  • 5 g vibration, 100 g shock, sealed to IP66
  • Dual GigE ports (control and diagnostic)
  • Designed for MIL-STD-461/810/1275 compliance
  • Extensive built-in system diagnostics
  • No rotary cooling device
Military style, Modbus TCP-based data acquisition and control I/O Chassis with 4 slots for I/O
Software/Programming: How UEI solutions are used. Hosted - Connected to a PC with Windows, Linux, QNX, VxWorks, RTX, or similar OS. Hosted also is for OPC-UA, Modbus and EtherCAT. Standalone - Controller with Linux or VxWorks OS, Simulink I/O Target or UEILogger. Available options for this product are shown in the drop down menu.
CPU Configuration:
Solid State Hard Drive:
SD Card:
M.2 Solid State Hard Drive:
Quantity: $10320
Add to Cart

Typically in stock for shipment in 3-4 weeks. Subject to global supply chain challenges.

UEIModbus 400-MIL

The UEIModbus™ Cubes are compact, rugged, Ethernet based data acquisition and control interface that communicates with a host computer or PLC over MODBUS TCP. The UEIModbus 400-MIL provides slots for 4 I/O boards. Its flexibility allows you to configure one or more Cubes or RACKs to match the specific I/O requirements of your application. The UEIModbus is ideally suited for a wide variety of industrial monitoring and control applications.

The Modbus messaging protocol was developed by Modicon in 1979 and is used to establish client-server communication between intelligent devices. It is a defacto standard, truly open and the most widely used network protocol in the industrial manufacturing environment. Modbus devices communicate using a client-server configuration. Only one device (the client) can initiate transactions (called queries). The other devices (servers) respond by supplying the requested data to the client, or by taking the action requested in the query.

The UEIModbus 400-MIL Cube functions as a Modbus server that is easily accessed by any software client acting as a Modbus client. Most popular HMI software supports the Modbus protocol.

The UEIModbus supports all AI, AO, DI, DO and CT layers that are compatible with UEI's Rack architecture. Analog input channels are read using two input registers encoded as a single 32-bit floating point value. Analog output channels are written to using two holding registers encoded as one 32-bit floating point value. Digital input ports are read using one or two input registers (depending on the port width). Each digital input line is also available as a discrete input register. Digital output ports are written using one or two holding registers (depending on the port width) and similar to the digital inputs, each digital output line is also available as a coil register. Counter or quadrature encoder inputs are read using one or two input registers (depending on the counter resolution).

The UEIModbus 400-MIL Cube, an data acquisition and I/O platform housed in a compact 6.2" x 7.1" x 8.7" chassis. The UEIModbus 400-MIL is is designed to meet MIL-STD-810 and MIL-STD-461 (including all power supply requirements), and supports virtually any input, any sensor, any interface I/O.

Designed for use in the toughest environments, the UEIModbus 400-MIL is an ideal solution for military and commercial applications including use on oil drilling platforms and refineries, heavy machinery, outdoor test stands and any other I/O application that will be exposed to the elements. All connectivity is through ROHS compliant 38999 connectors. The ruggedized chassis is easily configured as a stand-alone I/O controller or embedded, programmed and hardened for integration with high density, multifunction data acquisition systems. Its highly advanced architecture provides users with a simple and universal software API to construct, add and reconfigure applications based upon the I/O layers.

Related Media

Setting Up Your UEI System For Modbus

UEI's implementation of Modbus allows for quick and easy configuration of a Modbus TCP/IP server. Through the use of a web configurator, the Modbus Server is up and ready to go immediately. #hardware #IO #client #software #guardian #diagnostics #howto #guide

Learn more about UEI's Guardian Series Advantage at https://www.ueidaq.com/guardia...
Explore UEI's embedded system solutions at https://www.ueidaq.com/program...

UEI Technical Master Class: OPC-UA & Modbus

In this Master Class, we look at two popular Industrial Communication Protocols, Modbus, and also a newer protocol, OPC-UA. Takeaways include providing an overview of the two protocols, highlighting the benefits and limitations of each, and demonstrating UEI hardware using each of them. #rtu #IO #data #software #guide #demo

Learn more about UEI's embedded system solutions at https://www.ueidaq.com/program...
Learn more about UEI's software options at https://www.ueidaq.com/support...
Explore UEI's Technical Master Class series: https://youtube.com/playlist?l...